home *** CD-ROM | disk | FTP | other *** search
EISA add-on card Configuration | 1994-06-21 | 8.8 KB | 292 lines |
- ;╔═════════════════════════════════════════════════════════════════╗
- ;║ ║
- ;║ HP ISA 16/4 Token-Ring Network Adapter ║
- ;║ Adapter Configuration File Version 1.20 ║
- ;║ Copyright (C) 1990 by Hewlett Packard ║
- ;║ ║
- ;╚═════════════════════════════════════════════════════════════════╝
-
- BOARD
- ID = "OLC0701"
- NAME = "HP ISA 16/4 Token-Ring Network Adapter (D2378A)"
- MFR = "HP"
- CATEGORY = "NET"
- SLOT = ISA8OR16
- LENGTH = 167
- AMPERAGE = 1100
- SKIRT = NO
- READID = NO
- BUSMASTER = 1
- IOCHECK = INVALID
- DISABLE = UNSUPPORTED
-
- COMMENTS = "\nThis is the HP ISA 16/4 dual-speed
- (16 Mbps or 4 Mbps) Token Ring Network adapter
- card for ISA and EISA bus computers.\n\n
- The configuration utility will select a conflict-free
- configuration of system resources, and suggest switch
- settings for the adapter. These should be viewed on
- exit from the utility and set manually on the card
- before operation"
-
- SWITCH(1) = 2
- NAME = "SW1 RingSpeed switch"
- STYPE = SLIDE
- VERTICAL = NO
- REVERSE = YES
- LABEL = LOC(1 2) "16" "4"
- FACTORY = LOC(1 2) 01
- COMMENTS = "This is the 2-position Ring Speed slide-switch."
-
- SWITCH(2) = 12
- NAME = "SW2 Config. switch"
- STYPE = DIP
- VERTICAL = NO
- REVERSE = NO
- LABEL = LOC(1-12) "EN" "17" "16" "15" "14" "13"
- "I1" "I0" "A1" "A0" "D1" "D0"
- FACTORY = LOC(1-12) 111001110011
- COMMENTS = "This is the 12-position configuration dip-switch.
- Please refer to the Lan Administrator's Manual for an
- explanation of switch settings."
-
- FUNCTION = "Token-Ring Network Adapter"
- TYPE = "NET,TOK"
- CONNECTION = "9-Pin D-Socket: Token Ring Shielded Twisted
- Pair (Type 1) Lobe Cable"
-
- SUBFUNCTION = "I/O Address Location"
- COMMENTS = "\nUp to four HP Token-Ring Network adapters
- may be installed in this computer. An adapter must
- use one of four I/O port address combinations.
- Each combination consists of two address ranges.\n
- Use the VIEW SWITCH & JUMPER SETTINGS function
- to display the required switch settings."
-
- CHOICE = "0 = 0A20-0A23 & 0A30-0A3F"
- LINK
- PORT = 0A20h-0A23h
- SHARE = NO
- SIZE = BYTE
- PORT = 0A30h-0A3Fh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(2) LOC(9 10) 00
- CHOICE = "1 = 0A24-0A27 & 0A40-0A4F"
- LINK
- PORT = 0A24h-0A27h
- SHARE = NO
- SIZE = BYTE
- PORT = 0A40h-0A4Fh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(2) LOC(9 10) 10
- CHOICE = "2 = 0A50-0A53 & 0A60-0A6F"
- LINK
- PORT = 0A50h-0A53h
- SHARE = NO
- SIZE = BYTE
- PORT = 0A60h-0A6Fh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(2) LOC(9 10) 01
- CHOICE = "3 = 0A54-0A57 & 0A70-0A7F"
- LINK
- PORT = 0A54h-0A57h
- SHARE = NO
- SIZE = BYTE
- PORT = 0A70h-0A7Fh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(2) LOC(9 10) 11
-
- SUBFUNCTION = "Adapter Data Rate"
- TYPE = "SPD"
- COMMENTS = "\nThis Token-Ring Network adapter can operate
- at two different data rates, 4 Mbps or 16 Mbps.
- You MUST set the adapter data rate to the same
- rate as the Token-Ring Network LAN segment to
- which you are connecting the adapter.\n
- Use the VIEW SWITCH & JUMPER SETTINGS function
- to display the required switch setting."
-
- CHOICE = "4 Mbps"
- SUBTYPE = "4"
- FREE
- INIT = SWITCH(1) LOC(1 2) 01
- CHOICE = "16 Mbps"
- SUBTYPE = "16"
- FREE
- INIT = SWITCH(1) LOC(1 2) 10
-
- SUBFUNCTION = "RPL EPROM Address Location"
- COMMENTS = "\nThere are 12 possible 8K blocks of PC memory
- for the RPL EPROM area. The Preferred address
- location is: CC000-CDFFF.\n
- Use the VIEW SWITCH & JUMPER SETTINGS function
- to display the required switch settings."
-
- CHOICE = "EPROM Disabled"
- LINK
- INIT = SWITCH(2) LOC(1-6) 111001
- CHOICE = "CC000-CDFFF"
- LINK
- MEMORY = 8K
- ADDRESS = 0CC000h
- WRITABLE = NO
- SIZE = BYTE
- INIT = SWITCH(2) LOC(1-6) 011001
- CHOICE = "CE000-CFFFF"
- LINK
- MEMORY = 8K
- ADDRESS = 0CE000h
- WRITABLE = NO
- SIZE = BYTE
- INIT = SWITCH(2) LOC(1-6) 011000
- CHOICE = "D0000-D1FFF"
- LINK
- MEMORY = 8K
- ADDRESS = 0D0000h
- WRITABLE = NO
- SIZE = BYTE
- INIT = SWITCH(2) LOC(1-6) 010111
- CHOICE = "D2000-D3FFF"
- LINK
- MEMORY = 8K
- ADDRESS = 0D2000h
- WRITABLE = NO
- SIZE = BYTE
- INIT = SWITCH(2) LOC(1-6) 010110
- CHOICE = "D4000-D5FFF"
- LINK
- MEMORY = 8K
- ADDRESS = 0D4000h
- WRITABLE = NO
- SIZE = BYTE
- INIT = SWITCH(2) LOC(1-6) 010101
- CHOICE = "D6000-D7FFF"
- LINK
- MEMORY = 8K
- ADDRESS = 0D6000h
- WRITABLE = NO
- SIZE = BYTE
- INIT = SWITCH(2) LOC(1-6) 010100
- CHOICE = "D8000-D9FFF"
- LINK
- MEMORY = 8K
- ADDRESS = 0D8000h
- WRITABLE = NO
- SIZE = BYTE
- INIT = SWITCH(2) LOC(1-6) 010011
- CHOICE = "DA000-DBFFF"
- LINK
- MEMORY = 8K
- ADDRESS = 0DA000h
- WRITABLE = NO
- SIZE = BYTE
- INIT = SWITCH(2) LOC(1-6) 010010
- CHOICE = "DC000-DDFFF"
- LINK
- MEMORY = 8K
- ADDRESS = 0DC000h
- WRITABLE = NO
- SIZE = BYTE
- INIT = SWITCH(2) LOC(1-6) 010001
- CHOICE = "DE000-DFFFF"
- LINK
- MEMORY = 8K
- ADDRESS = 0DE000h
- WRITABLE = NO
- SIZE = BYTE
- INIT = SWITCH(2) LOC(1-6) 010000
- CHOICE = "C8000-C9FFF"
- LINK
- MEMORY = 8K
- ADDRESS = 0C8000h
- WRITABLE = NO
- SIZE = BYTE
- INIT = SWITCH(2) LOC(1-6) 011011
- CHOICE = "CA000-CBFFF"
- LINK
- MEMORY = 8K
- ADDRESS = 0CA000h
- WRITABLE = NO
- SIZE = BYTE
- INIT = SWITCH(2) LOC(1-6) 011010
-
- SUBFUNCTION = "Interrupt Level"
- TYPE = "INT"
- COMMENTS = "\nThis Token-Ring Network adapter can operate
- on one of four interrupt levels: 2 (9), 3, 10,
- or 11. The preferred interrupt level is 2 (9).\n
- NOTE that the adapter only uses edge-triggered
- interrupts.\n
- Use the VIEW SWITCH & JUMPER SETTINGS function
- to display the required switch settings."
-
- CHOICE = "Interrupt 2 (9)"
- SUBTYPE = "9"
- LINK
- IRQ = 9
- SHARE = NO
- TRIGGER = EDGE
- INIT = SWITCH(2) LOC(7 8) 11
- CHOICE = "Interrupt 3"
- SUBTYPE = "3"
- LINK
- IRQ = 3
- SHARE = NO
- TRIGGER = EDGE
- INIT = SWITCH(2) LOC(7 8) 10
- CHOICE = "Interrupt 10"
- SUBTYPE = "10"
- LINK
- IRQ = 10
- SHARE = NO
- TRIGGER = EDGE
- INIT = SWITCH(2) LOC(7 8) 01
- CHOICE = "Interrupt 11"
- SUBTYPE = "11"
- LINK
- IRQ = 11
- SHARE = NO
- TRIGGER = EDGE
- INIT = SWITCH(2) LOC(7 8) 00
-
- SUBFUNCTION = "Data Transfer Mode"
- TYPE = "DMA"
- COMMENTS = "\nThis Token-Ring Network adapter can operate
- on one of three DMA levels: 5, 6 or 7 as a Bus
- Master. The preferred DMA level is 5.\n
- Use the programmed I/O transfer mode as an
- alternative to the Bus Master mode.\n
- Use the VIEW SWITCH & JUMPER SETTINGS function
- to display the required switch settings."
-
- CHOICE = "Bus master - DMA level 5"
- SUBTYPE = "Master5"
- LINK
- DMA = 5
- SHARE = NO
- TIMING = DEFAULT
- INIT = SWITCH(2) LOC(11 12) 11
- CHOICE = "Bus master - DMA level 6"
- SUBTYPE = "Master6"
- LINK
- DMA = 6
- SHARE = NO
- TIMING = DEFAULT
- INIT = SWITCH(2) LOC(11 12) 10
- CHOICE = "Bus master - DMA level 7"
- SUBTYPE = "Master7"
- LINK
- DMA = 7
- SHARE = NO
- TIMING = DEFAULT
- INIT = SWITCH(2) LOC(11 12) 01
- CHOICE = "Programmed I/O transfer"
- SUBTYPE = "PIO"
- LINK
- INIT = SWITCH(2) LOC(11 12) 00
-